DC Power Voltage / Vertically- Or Horizontally- Oriented Pump Head
The HRP series is powered by 12 VDC or 24 VDC and offers an ideal fit for built-in applications. Select vertically- or horizontally- oriented pump head to get optimum mounting position in various host machines.
High Resolution
Digitally-controlled spm range is 0 – 720 spm. The minimum flow of 0.055 mL per shot offers a constant micro-injection * The stop control type does not allow variable control of the number of strokes.
Waterproof and Dustproof Structure
The sealed drive unit and control unit are enclosed to a water/dust-proof rating of IP65. * This pump is not completely water proof. Protect the pump with a cover when installing it out of doors.
Operational function
HRP pumps are controlled by an external signal and are available in the following types:
Pulse control type
A pulse signal input controls pump operation (stroke rate). The pump makes one shot per pulse synchronously. • An input signal is required to enable operation in addition to power activation for this type. • The pump can not exceed a maximum of 720 spm, even if the external signal input instructs the pump to run beyond that speed.
1 – 5 V control type
The input of 1 – 5 V proportionally controls the pump operation (stroke rate). • An input signal is required to enable operation in addition to power activation for this type.
4 – 20 mA control type
The input of 4 – 20 mA proportionally controls the pump operation (stroke rate). • An input signal is required to enable operation in addition to power activation for this type.
Stop control type
The input of the stop signal suspends the pump operation. • The pump starts to run at 720 spm upon power activation for this type.
Request Info
Call
+45 4824 2345
info@iwaki.dk
Product details
Materals
PVDF, FKM, ceramic, PTFE
Weight
0,5 kg
Max Flow
Up to 38 mL/min
Max. Operating pressure
0,2 MPa
Voltage
12V DC or 24V DC
Tube connection bore
Stroke rate
0-720 spm
Operational function
Pulse / 4-20mA / 1-5V / stop